Schneider Electric ION9000 ION9000 — En üst seviye utility / data center ölçümü. Sınıf 0.2S, tam PQ, IEC 61850.
🔗
Schneider Electric
Official product page (se.com)
● 52 Argus Registers — Ready Template
ION9000

ION9000

The PowerLogic ION9000 is Schneider Electric's top-of-range power meter for utility and data centre applications. Class 0.2S accuracy, full IEC 61000-4-30 Class A power quality analysis and IEC 61850 communication make it ready for next-generation smart grid integration.

Measurement Channels
AccuracyClass 0.2S — utility grade
HarmonicsThe most comprehensive harmonic analysis
Power QualityIEC 61000-4-30 Class A — transients + flicker
EnergyRevenue grade, all parameters
ProtocolIEC 61850 · Modbus TCP · DNP3
Technical Specifications
AccuracyClass 0.2S (IEC 62053-22)
PQ StandardIEC 61000-4-30 Class A
CommunicationIEC 61850 · Ethernet Modbus TCP · DNP3
ApplicationUtility / Data Centre / Large facility

Integration with Argus EMS

The ION9000 connects to Argus EMS over Modbus TCP over Ethernet, and because a ready register template ships with the platform you do not have to work out a point map on site. The field agent polls the device every 60 seconds by default, writes the reading into a local queue first and then forwards it to the server over MQTT/TLS; nothing is deleted before the server acknowledges it. Hourly and daily summaries are derived from these raw readings, and the consumption and cost screens are fed from the same series.

ProtocolModbus TCP over Ethernet
Connection pathDirectly over Modbus TCP (port 502) — no separate gateway is needed
Default polling period60 seconds (field agent)
Points in the ready template52 registers
Consumption calculationDifference of the kWh import index over the period (MAX − MIN)
Data assuranceLocal queue plus server acknowledgement; nothing is deleted before it is confirmed

When Is This Model the Right Choice?

This is a utility-class metering device combining meter accuracy class, event logging and waveform capture. It is used at points where a metering difference with the distribution company is disputed, or where contracted demand is managed closely.

The device serves Modbus TCP directly over Ethernet, so no gateway is needed. In exchange, each device needs an IP address on the network and a switch port inside the panel. If more than one master polls the same device at once — a building automation system alongside Argus EMS, for example — its concurrent connection limit has to be respected.

Frequently Asked Questions

How is the ION9000 connected to Argus EMS?
It connects over Modbus TCP over Ethernet: directly over Modbus TCP (port 502) — no separate gateway is needed. The field agent polls the device every 60 seconds by default, writes the readings into a local queue and forwards them to the server over MQTT/TLS. If the link drops the data waits in the queue and is backfilled once the connection returns.
Does the ION9000 need a register map to be worked out separately?
No. A ready template with 52 points is defined in Argus EMS; you pick the template when adding the device and enter its address and slave ID. The point-by-point mapping step on site disappears, and the same model is read with the same template in every project.
Can the Schneider Electric ION9000 measurement be compared with the electricity invoice?
Yes. The measured kWh index is placed side by side with the invoice from the distribution company, and the distribution charge, YEKDEM and reactive items are shown separately. Bill reconciliation therefore rests on your own meter's index rather than on an estimate.