Integration with Schneider, ABB, Siemens, Zenner, Socomec and hundreds more via Modbus TCP/RTU, M-Bus TCP, and DSE protocols.
Argus EMS is brand independent: it reads any device speaking Modbus TCP/RTU, M-Bus TCP, SNMP or DSE — energy analyzers, transformer meters, water and heat meters, UPS units and genset controllers. Where a register template exists, a new model is defined in minutes; where it does not, the device map is derived and added to the template library. No device replacement required.
| Protocol | Use Case | Connection | Example Devices |
|---|---|---|---|
| Modbus TCP | Energy analyzers, transformer meters | Ethernet / RJ-45 | Schneider PM5xxx, Siemens SENTRON, ABB B-serisi |
| Modbus RTU | Legacy meters, RS-485 panels | RS-485 / USB-RS485 converter | Eastron SDM, Carlo Gavazzi, Chint DDSU |
| M-Bus TCP | Water meters, heat meters | Ethernet M-Bus Gateway | Zenner MBUS, Kamstrup, Sensus |
| DSE Genset | Generator control units | Ethernet / Modbus | DSE 7xxx/8xxx serisi, ComAp InteliGen |
| SNMP | UPS systems | Ethernet | APC Smart-UPS, Eaton 9xxx, Huawei UPS |
Power transformers, compensation panels, energy analyzers. kW, kVAr, kVA, PF, harmonics, voltage, current. Single and three-phase.
Online/offline UPS, battery level, remaining runtime, bypass status, load percentage. Dual-protocol support via SNMP and Modbus.
Diesel/gas generators. Start/stop events, fuel level, engine hours, phase voltage, load percentage.
Water meters via M-Bus TCP gateway. Instantaneous flow, cumulative volume, tariff-based consumption tracking.
PV inverter production tracking, DC/AC conversion efficiency, string currents, daily/monthly production trends.
Transformer room temperature, humidity, door contact. Automatic alarm email on critical threshold breach.
PowerLogic energy analyzer: Modbus TCP connection, measurement channels and a ready Argus register template.
View →SENTRON energy analyzer: register map, commissioning in minutes and a field-verified template.
View →DSE 7xxx/8xxx genset controllers: start/stop events, fuel level, engine hours and alarm monitoring.
View →Zenner and other M-Bus water meters: gateway connection, cumulative index and consumption tracking.
View →Air-cooled chiller: water temperatures, load percentage, alarm codes and remote setpoint integration.
View →Rhoss chillers: evaporator water temperatures, compressor status, load and alarms with a ready template.
View →Reactive power control relay: energy indexes, inductive/capacitive ratios and capacitor step status.
View →A small software agent is installed on-site. It only needs to be on the same local network as the devices — no complex infrastructure required.
Argus automatically finds devices on the network using a Modbus scanner.
Select brand/model from the ready template library; the register map loads automatically.
Accuracy of first readings is verified from the live dashboard.
Alarm thresholds and tariff parameters are entered; monitoring begins.
See also: energy analyzer monitoring and supported analyzer models.
Explore the system with your own data in a demo session.