York YVAA Air-Cooled Screw Chiller — Real-time power, energy and alarm monitoring via Modbus TCP protocol with Argus EMS.

All Devices →

What Data Do We Read?

Leaving Water Temperature°C
Return Water Temperature°C
Outdoor Air Temperature°C
Cooling Load%
Motor Current% FLA
Evaporator Pressurebar
Condenser Pressurebar
Chilled Water Setpoint°C
Compressor Statuson/off
Alarm Codecode
Running Hourshours

How to Connect to Argus EMS

1

Physical Connection

Connect the device to the RS-485 or Ethernet network. Configure Slave ID and baud rate from the device front panel or web interface.

2

Add Device in Argus

From the Argus web panel click "New Device". Select York YVAA from the template list — the register map loads automatically.

3

Live Monitoring

The Field Agent tests the connection; the first reading appears on the dashboard within 60 seconds. Alarm thresholds are configured.

What Can You Monitor?

  • Leaving/return water and outdoor air temperatures
  • Cooling load and motor current (% FLA)
  • Evaporator / condenser pressures
  • Instant notification of alarm codes
  • Remote setpoint writing with signed commands
  • Rule-based day/night setpoint management
  • Correlation of chiller consumption with the energy analyzer
  • Running hours and start/stop history

Combined with Chiller Optimisation

The York YVAA integration is at its strongest with rule-based night mode and energy correlation. Details on the chiller optimisation solution page.

Chiller Optimisation →

Also: Argus EMS Platform · Rhoss Chiller

Frequently Asked Questions

How does the York YVAA connect to Argus EMS?
The YVAA control panel offers Modbus TCP communication; the chiller connects to the Field Agent over the existing LAN. Selecting the York YVAA template in Argus loads the parameter map automatically — a field-proven, ready template.
Can the setpoint be changed remotely?
Yes. The chilled water setpoint can be written from Argus with a signed, authorized command; only the defined safe range is accepted and every change is recorded in the audit trail.
Which alarms are monitored?
Fault codes produced by the YVAA are read instantly and fed to the alarm engine: code changes, compressor stops and abnormal pressure conditions generate email/panel notifications. Alarm history is stored with timestamps.