Mid-range RS485
Schneider Electric PM3250 PM3000 — Endüstriyel panolar için orta segment. 31. harmonik, 2DI/2DO, 256 KB bellek.
🔗
Schneider Electric
Official product page (se.com)
● 38 Argus Registers — Ready Template
PM3000

PM3250

The PowerLogic PM3250 is a dependable choice for industrial applications and mid-range energy monitoring projects. Measurement up to the 31st harmonic, 2DI/2DO and 256 KB of data memory strengthen its alarm and logging capacity.

Measurement Channels
Voltage / CurrentPhase-neutral, line-line, neutral current
PowerkW / kVAr / kVA — phase + total
HarmonicsUp to the 31st harmonic — V + I THD
Reactive EnergyQ1 kVArh + Q4 kVArh
EnergykWh + kVArh + kVAh — import/export
Min/MaxVoltage, current, power — time stamped
Technical Specifications
AccuracyClass 0.5S (IEC 62053-22)
CommunicationRS485 Modbus RTU
Memory256 KB
I/O2 digital inputs · 2 digital outputs
Alarms35 configurable alarms
Mounting96×96 mm panel front · DIN rail
Power Supply100–415 V AC

Integration with Argus EMS

The PM3250 connects to Argus EMS over Modbus RTU over an RS-485 serial line, and because a ready register template ships with the platform you do not have to work out a point map on site. The field agent polls the device every 60 seconds by default, writes the reading into a local queue first and then forwards it to the server over MQTT/TLS; nothing is deleted before the server acknowledges it. Hourly and daily summaries are derived from these raw readings, and the consumption and cost screens are fed from the same series.

ProtocolModbus RTU over an RS-485 serial line
Connection pathThe RS-485 line lands on a Modbus TCP gateway or on the field PC serial port
Default polling period60 seconds (field agent)
Points in the ready template38 registers
Consumption calculationDifference of the kWh import index over the period (MAX − MIN)
Data assuranceLocal queue plus server acknowledgement; nothing is deleted before it is confirmed

When Is This Model the Right Choice?

It suits metering mid-sized loads separately — floor panels, kitchens, laundries or a chiller. Energy, demand and power factor are tracked together, and the internal breakdown of consumption becomes meaningful from this level onwards.

The device has a serial output, so it joins the existing RS-485 line instead of requiring a dedicated Ethernet run into the panel. The more devices share one line, the longer a polling round takes, which is why the field agent reads each line sequentially and waits 60 ms between devices by default. A slave ID collision and a missing line termination are the two most common commissioning mistakes.

Frequently Asked Questions

How is the PM3250 connected to Argus EMS?
It connects over Modbus RTU over an RS-485 serial line: the RS-485 line lands on a Modbus TCP gateway or on the field PC serial port. The field agent polls the device every 60 seconds by default, writes the readings into a local queue and forwards them to the server over MQTT/TLS. If the link drops the data waits in the queue and is backfilled once the connection returns.
Does the PM3250 need a register map to be worked out separately?
No. A ready template with 38 points is defined in Argus EMS; you pick the template when adding the device and enter its address and slave ID. The point-by-point mapping step on site disappears, and the same model is read with the same template in every project.
Can the Schneider Electric PM3250 measurement be compared with the electricity invoice?
Yes. The measured kWh index is placed side by side with the invoice from the distribution company, and the distribution charge, YEKDEM and reactive items are shown separately. Bill reconciliation therefore rests on your own meter's index rather than on an estimate.