← All Products
Professional Ethernet
Schneider Electric PM5320 PM5000 — SCADA entegrasyonu için Ethernet, 63. harmonik, genişletilmiş kayıt kapasitesi.
🔗
Schneider Electric
Official product page (se.com)
● 43 Argus Registers — Ready Template
PM5000

PM5320

The PowerLogic PM5320 is designed for integration into SCADA and energy management systems over Ethernet. It monitors critical energy points with measurement up to the 63rd harmonic and advanced data logging capacity.

Measurement Channels
Voltage / CurrentPhase-neutral, line-line, neutral current
HarmonicsUp to the 63rd harmonic — VTHD + ITHD L1/L2/L3
Reactive EnergyQ1 + Q4 kVArh — inductive + capacitive
EnergykWh import/export · kVArh · kVAh
Min/MaxTime-stamped records
Technical Specifications
AccuracyClass 0.5S (IEC 62053-22)
CommunicationEthernet Modbus TCP
Mounting96×96 mm panel front
Power Supply100–415 V AC

Integration with Argus EMS

The PM5320 connects to Argus EMS over Modbus TCP over Ethernet, and because a ready register template ships with the platform you do not have to work out a point map on site. The field agent polls the device every 60 seconds by default, writes the reading into a local queue first and then forwards it to the server over MQTT/TLS; nothing is deleted before the server acknowledges it. Hourly and daily summaries are derived from these raw readings, and the consumption and cost screens are fed from the same series.

ProtocolModbus TCP over Ethernet
Connection pathDirectly over Modbus TCP (port 502) — no separate gateway is needed
Default polling period60 seconds (field agent)
Points in the ready template43 registers
Consumption calculationDifference of the kWh import index over the period (MAX − MIN)
Data assuranceLocal queue plus server acknowledgement; nothing is deleted before it is confirmed

When Is This Model the Right Choice?

It is built for main distribution boards and critical loads: alongside energy and demand, the basic power quality quantities are reported too. Reactive penalty tracking and compensation assessment become reliable from this level upwards.

The device serves Modbus TCP directly over Ethernet, so no gateway is needed. In exchange, each device needs an IP address on the network and a switch port inside the panel. If more than one master polls the same device at once — a building automation system alongside Argus EMS, for example — its concurrent connection limit has to be respected.

Frequently Asked Questions

How is the PM5320 connected to Argus EMS?
It connects over Modbus TCP over Ethernet: directly over Modbus TCP (port 502) — no separate gateway is needed. The field agent polls the device every 60 seconds by default, writes the readings into a local queue and forwards them to the server over MQTT/TLS. If the link drops the data waits in the queue and is backfilled once the connection returns.
Does the PM5320 need a register map to be worked out separately?
No. A ready template with 43 points is defined in Argus EMS; you pick the template when adding the device and enter its address and slave ID. The point-by-point mapping step on site disappears, and the same model is read with the same template in every project.
Can the Schneider Electric PM5320 measurement be compared with the electricity invoice?
Yes. The measured kWh index is placed side by side with the invoice from the distribution company, and the distribution charge, YEKDEM and reactive items are shown separately. Bill reconciliation therefore rests on your own meter's index rather than on an estimate.

See Argus at Your Facility