Professional+ Ethernet
Schneider Electric PM5560 PM5000 — Kritik yükler için gelişmiş PQ izleme, Ethernet, genişletilmiş I/O ve kayıt.
🔗
Schneider Electric
Official product page (se.com)
● 43 Argus Registers — Ready Template
PM5000

PM5560

The PowerLogic PM5560 offers advanced power quality monitoring, comprehensive communication and extended I/O options at critical load points. It is the preferred meter in data centres, hospitals and large industrial facilities.

Measurement Channels
Voltage / CurrentFull phase measurement — all parameters
HarmonicsAdvanced harmonic analysis
Reactive EnergyQ1 + Q4 kVArh
EnergykWh + kVArh + kVAh — import/export
Power QualityPQ event logging
Technical Specifications
AccuracyClass 0.5S (IEC 62053-22)
CommunicationEthernet Modbus TCP
Mounting96×96 mm panel front

Integration with Argus EMS

The PM5560 connects to Argus EMS over Modbus TCP over Ethernet, and because a ready register template ships with the platform you do not have to work out a point map on site. The field agent polls the device every 60 seconds by default, writes the reading into a local queue first and then forwards it to the server over MQTT/TLS; nothing is deleted before the server acknowledges it. Hourly and daily summaries are derived from these raw readings, and the consumption and cost screens are fed from the same series.

ProtocolModbus TCP over Ethernet
Connection pathDirectly over Modbus TCP (port 502) — no separate gateway is needed
Default polling period60 seconds (field agent)
Points in the ready template43 registers
Consumption calculationDifference of the kWh import index over the period (MAX − MIN)
Data assuranceLocal queue plus server acknowledgement; nothing is deleted before it is confirmed

When Is This Model the Right Choice?

It extends the professional measurement set and is preferred for main incomers, transformer outgoers and large mechanical loads. Energy, demand, power factor and harmonic indicators come from a single device, so no separate analyser is needed inside the panel.

The device serves Modbus TCP directly over Ethernet, so no gateway is needed. In exchange, each device needs an IP address on the network and a switch port inside the panel. If more than one master polls the same device at once — a building automation system alongside Argus EMS, for example — its concurrent connection limit has to be respected.

Frequently Asked Questions

How is the PM5560 connected to Argus EMS?
It connects over Modbus TCP over Ethernet: directly over Modbus TCP (port 502) — no separate gateway is needed. The field agent polls the device every 60 seconds by default, writes the readings into a local queue and forwards them to the server over MQTT/TLS. If the link drops the data waits in the queue and is backfilled once the connection returns.
Does the PM5560 need a register map to be worked out separately?
No. A ready template with 43 points is defined in Argus EMS; you pick the template when adding the device and enter its address and slave ID. The point-by-point mapping step on site disappears, and the same model is read with the same template in every project.
Can the Schneider Electric PM5560 measurement be compared with the electricity invoice?
Yes. The measured kWh index is placed side by side with the invoice from the distribution company, and the distribution charge, YEKDEM and reactive items are shown separately. Bill reconciliation therefore rests on your own meter's index rather than on an estimate.